misting systems

Pocket Panda Outdoor Misting Cooling System with Kit

The misting systems is used on Patio/balconies, outdoor dining areas, outdoor activity venues, and swimming pool areas. Especially in hot weather, it plays a crucial role in alleviating the heatstroke caused by extended stays in summer caused by high temperatures. Pocket Panda outdoor misting kits are an excellent option with the best outdoor cooling experience
Our Story Reading Pocket Panda Outdoor Misting Cooling System with Kit 15 minutes Next Pocket Panda Greenhouse Misting Kit

 

The "pocket panda outdoor misting cooling system (with Kit)" is an innovative Mist Expansion Kit, crafted as a highly efficient solution aimed at adjusting to local temperature fluctuations. Pocket Panda has explored an array of cooling efficiency expansion solutions, meticulously designed to provide relief from the heat across diverse environmental conditions. These DIY outdoor misting system utilizes a fine mist to lower temperatures in the immediate area, rendering it perfect for enhancing comfort in patios, decks, gardens, or any outdoor spaces where people gather.

outdoor misting kits

 

Firstly, these outdoor misting kits are available in a variety of sizes and configurations to suit any size patio or outdoor space. You can choose the size and model that suits your needs, ensuring even cooling throughout the area. From small patios to large outdoor spaces, you can find the right kit.

 

Secondly, these outdoor misting kits compact design, easy to install and operate. Typically includes nozzles, pipes and connectors and can be simply installed around your patio or outdoor space. Once installed, simply open the valve and the misting systems can begin working. This convenience allows you to enjoy a cooling and refreshing experience without the need for complicated tools or professional help.Pocket Panda Mist Expansion Kit utilizes a fine mist to lower temperatures in the immediate area, making it ideal for patios, decks, gardens, or any outdoor gathering spaces.

 

How to Match Reasonable Kits

When shopping for misting systems, consider that the type and number of nozzles will match your spraying needs, the connectors should be sturdy and durable to prevent leaks, the timers will increase the convenience of control, the automatic water refill connector will keep the system running, and the anti-corrosion materials and filters should The network helps the system to operate stably in the long term. Checking the quality and functionality of these accessories will ensure the selected system will operate reliably and efficiently in the outdoor environment

A reasonable combination of outdoor misting kit accessories can ensure the best cooling effect and user experience for outdoor scenes. Depending on your specific needs and outdoor scenes, you may need to customize a particular combination of accessories. You can follow the following points.

  • Venue size
  • Usage requirements
  • Environmental characteristics
  • Durability and installation
  • Control and management

 

Case: Assuming there is an outdoor terrace with an area of about 50 square meters, about 10-15 nozzles can be arranged, evenly distributed on the edge of or above the terrace. Use a hidden piping layout to maintain aesthetics, and use a smart pump that can regulate flow. In addition, several large parasols are installed to provide people with shade while also increasing the cooling effect.

Misting Cooling Systems Combined With Parasols or Shade Cloths

 

  • Large umbrella/shade cloth: Choose a large, high-quality umbrella or shade cloth that can cover the entire patio area. These shading features not only provide shade, but can also be used as part of a mist system to optimize the effect of the mist.
  • The nozzles are installed on the sunshade facilities: install the nozzles on the edge of the parasol or under the sunshade cloth. This allows the spray to cover the entire area more evenly, while also preventing the mist from coming into direct contact with people.

 Each equipped with fine nozzles on the edge. These nozzles are connected to the main water pump through pipes hidden within the umbrella frame. The entire system can be managed from a central control unit, allowing staff to adjust the intensity of the misters according to weather changes or customer demand. This layout provides the necessary shade and creates a relaxed and comfortable dining environment.

Outdoor Misting System or Fan Mist Cooling Kit for BBQ Party

Enhance the ambiance of your BBQ party with the 'Outdoor Misting System or Fan Mist Cooling Kit'. These systems can be used together or independently, adapting to the changing intensities of summer heat. Initially, as the heat starts to build, you might employ the fan kit for immediate relief. As the space and need for cooling expand, the outdoor misting system can be utilized to design a cooling zone or used in conjunction with mist umbrellas. On the hottest days, combining both ensures that you and your guests stay comfortable. The fine mist they emit cools the air around the outdoor cooking and dining areas, not only providing a cooling effect but also enhancing the atmosphere, offering your guests a more enjoyable and refreshing experience."

Combining an Outdoor Misting System With a Fan Mist Cooling Kit The Key Benefits:

Fan Mist Cooling Kit for BBQ Party

  • Enhanced Cooling Effect: The misting system reduces the temperature by evaporating water into the air, while the fan helps to circulate the cooled air more efficiently. When used together, they can lower the ambient temperature more effectively than either system could alone.
  • Increased Comfort in Larger Areas: Fans can push the cool mist further into the outdoor space, extending the cooling effect to cover a larger area. This is particularly beneficial for accommodating more guests at outdoor events.
  • Improved Air Quality: The mist helps to settle dust particles and pollen, which the fan then disperses, leading to cleaner air around the entertainment area.
  • Flexible Cooling Options: By combining these systems, you can adjust the level of cooling based on current weather conditions and the specific needs of your gathering. For instance, on extremely hot days, both systems can be maximized for cooling, while on milder days, perhaps only one system might be necessary.
  • Energy Efficiency: Despite their combined cooling power, misting systems and fan kits are generally more energy-efficient compared to traditional air conditioning units, making them a cost-effective solution for outdoor cooling.
  • Enhanced Atmosphere: The gentle breeze from the fans and the visual effect of the mist can create a more pleasant and inviting atmosphere for guests, enhancing the overall experience of the outdoor event.
  • Versatility: This combination can be used in various settings, from small backyard BBQs to larger outdoor gatherings, offering flexibility to meet the needs of any event size.

How to Assess the Right Size for Your Venue

 

Evaluating the appropriate site size requires a combination of nozzle type, system coverage, water pressure, environmental characteristics, and professional advice. Choosing a misting system that meets your needs and provides effective cooling within the confines of your specific site is key.

Measure the site dimensions

 First, measure the patio's length, width, and height or intended installation area. These dimensions determine the number and layout of nozzles required.

  • Small venues: Choose a small size kit, such as one with a lower number of nozzles, to ensure even coverage.
  • Large venues: Requires larger size kits to cover a wider area and may require more nozzles and stronger water pressure

Determine the Misting Nozzle Coverage

If you choose an atomizing nozzle for low pressure spray. Low-pressure atomizing nozzles are designed to atomize water or other liquids into a fine mist at relatively low operating pressures, typically 10 to 50 PSI (pounds per square inch). The spray cone angle, penetration distance and speed of methanol will change when the nozzle aperture, inlet curvature radius and taper are different.

Misting Nozzle

  • Small Diameter: Think of small-diameter nozzles as the fine artists of misting. They produce a delicate mist that’s perfect for cooling without drenching. These are your go-to choice for creating a gentle, refreshing cloud on a hot summer’s day.
  • Large Diameter: On the other hand, large-diameter nozzles are like the firehoses of the misting world. They can produce a more substantial mist but might lean towards the wetter side. These are great for industrial applications or when you need to cool down an entire army of barbecue enthusiasts at your backyard party.Related Reference

For standard residential patio misting systems, which typically use high-pressure or low-pressure misting nozzles, a recommended spacing range is between 2 to 4 feet (approximately 0.6 to 1.2 meters) apart. This spacing allows for even coverage and ensures the mist is distributed effectively across the desired area without leaving any hot spots. However, the exact spacing may vary based on the misting nozzle’s flow rate and the desired level of cooling.

Calculate the Number of Nozzles and Layout

Use the coverage radius of the nozzles to calculate the total number of nozzles required. For example, if one nozzle covers a circular area of 2 meters radius (an area of approximately 12.57 square meters), the number of nozzles required can be estimated by dividing the total area by the area covered by a single nozzle

To ensure that no area is missed, there should be some overlap in the coverage of the nozzles. Generally speaking, the overlap between nozzles should be 20%-30%.

  • Even Distribution: Distribute nozzles evenly across the area, ensuring every corner is covered.
  • Consider wind direction: Adjust the position of the nozzle according to common wind directions to maximize spray effect.
  • Avoid Obstacles: Make sure the nozzle is not blocked by tall furniture or plants

Example calculation


Assuming a 10m x 10m area (total area 100m2), using nozzles with a coverage radius of 2m each (a single coverage area of approximately 12.57m2), allowing for a 20% overlap:

Coverage area of a single nozzle: π × (2 meters)^2 ≈ 12.57 square meters
Overlap adjustment: 12.57 square meters × (1 - 20%) ≈ 10.06 square meters
Number of nozzles required: 100 square meters / 10.06 square meters ≈ 10 pieces

Therefore, approximately 10 nozzles are needed to cover the entire area. Adjust quantity and layout according to the actual situation

Consider the Pipeline Layout

Plan the corresponding pipeline route according to the layout and number of nozzles. It is necessary to ensure the piping reaches all nozzles and is as hidden as possible.

Let's say you have an outdoor restaurant patio that is 20 meters long and 10 meters wide, and you plan to install a patio mister on the edge of the patio.

Measure and plan
Determine hose length: Start by measuring the total length around your patio. In this case, the full perimeter of the terrace is 2×(20+10)=60 meters.
Nozzle spacing: Assuming a nozzle is installed every 2 meters, 60 divided by 2 = 30 nozzles are needed.

Note that the hose must be aligned with the nozzle position
Nozzle Connections: The hose layout should ensure access to all nozzles. Plan the direction of the pipeline according to the position of the nozzle.
Nozzle Coverage: Ensure each nozzle receives adequate water pressure within its effective coverage area.

For an intuitive explanation, we can imagine a specific case.

  • Site dimensions: 10m x 10m terrace
  • Nozzle type: Each nozzle covers a radius of 2 meters
  • Number of nozzles required: Approximately 16
  • Pipe layout: arrange the pipes according to the nozzle position
  • Water pump: Choose the appropriate water pump according to the needs of 16 nozzles
  • Control system: intelligent control can adjust spray intensity and frequency

 

The picture above shows a schematic layout of a misting cooling system for a 10m x 10m terrace. You can see the location of the nozzles (small circles), the hidden pipe layout (dashed lines), and the location of the water pump and control system (boxes and rectangles). This diagram helps understand how to plan and lay out a misting cooling system based on the dimensions of a specific site.

How to Assess Needs

When assessing needs, the size of the site, such as whether it will be used for domestic leisure or commercial activities, must be considered to determine the extent and effectiveness of cooling required. Frequency of use, determining misting systems,frequency and time of use. Is it available around the clock or only during certain times? This will affect how the system is designed and controlled,

  • Environmental conditions: consider the area's temperature, humidity, and other environmental conditions. Muscular misting systems may be needed in hot and dry regions, while unique treatments may be required in humid areas to prevent scaling and other problems.
  • Functional requirements: do you need a specific type of nozzle? Things like adjustable or nozzles with broader coverage, resource sustainability, and budget constraints. These factors can help you choose the outdoor misting systems that best suit your needs.

To develop a detailed requirements plan, we can go further based on the layout plan discussed earlier. The following is a detailed requirements scenario that will cover all aspects to help users better understand the required misting systems

Site Characteristics and Use

Dimensions: 10m x 10m terrace.
Layout features: The terrace is open all around with no obstructions.
Purpose of use: Mainly used as a leisure and dining area

envirnmental factor

Climate: Warm and dry climate with high summer temperatures.
Seasonal use: Mainly used in summer.
Sunshine conditions: direct sunlight throughout the day

User needs and preferences

Cooling Goal: Want to lower the temperature in the patio area by 5 to 10 degrees Celsius.
Comfort requirements: Avoid slippery floors or excessive humidity.
Aesthetic requirements: system components should be as hidden as possible

Accessories requirements

Nozzles: 16 high-efficiency micro-mist nozzles are used, each nozzle covers a radius of about 2 meters.
Water pump: Choose a high-pressure or low-pressure water pump to ensure uniform and stable water mist output.
Pipes: use anti-corrosion materials and concealed layout.
Control system: intelligent control system, capable of remote operation and automatic adjustment function

 

Other Application Functions of Misting Kit

The misting cooling system adopts the principle of evaporation and heat absorption. Through the water source purified by the water treatment device, the misting device generates mist molecular particles (particle diameter is at the micron level), which are transported and diffused to the cooling area through the cooling fan. During the diffusion process, the misting cooling system continuously Evaporates and absorbs a large amount of heat energy in the area to achieve the purpose of cooling.

  • Outdoor-Indoor Temperature Balance: A patio misting system can help maintain a more consistent temperature between indoor and outdoor areas by cooling the outdoor space. This balance can reduce the thermal load on the air conditioner, especially if doors or windows are frequently opened.
  • Direct Cooling for Outdoor Units: If positioned appropriately, a misting system might indirectly aid the air conditioner by cooling the air around the outdoor unit of the air conditioner. This can potentially increase the efficiency of the heat exchange process in the outdoor unit, although care must be taken to avoid excess moisture, which could damage the unit.

To solve the problem of poor outdoor thermal environment for household air conditioners in summer, the misting system can be used to add a spray humidification device to the air conditioner to reduce the condensation temperature and thereby improve the performance and cooling capacity of the air conditioner. The impact of misting cooling system on air conditioner condenser outlet air temperature and refrigeration system performance. Actual measurement studies have found that after adding misting system humidification, the refrigerant pressure at the condenser outlet is reduced, and the performance coefficient EER of the refrigeration system can be increased by 2% to 7%, which is a significant effect.

The output of the air conditioner is blocked, increasing the power consumption of the air conditioner. To improve the air conditioner’s performance, a mister device is installed on the air conditioner’s outdoor unit. While ensuring the heat exchange area and ventilation volume are constant, the heat dissipation capacity of the condenser is enhanced, the air conditioning performance is improved, and the air conditioner’s power consumption is reduced. The purpose of reducing operating energy consumption

 Recommended related articles